Valve body: ASTM A 216 Grade WCB
Standard: Two fixed flanges
Lining: FEP in compliance with ASTM D 2116
PFA in compliance with ASTM D 3307, natural
Pure PTFE in compliance with ASTM D 1457, white in colour
Lining thickness: 3 to 5 mm, exceeds the relevant ASTM F-1545 standard specs.
Operating temperature: FEP -29 to 200 deg. C
Operating temperature: PTFE -29 to 260 deg. C
Operating temperature: PFA -29 to 260 deg. C
Operating pressure: Vaccume to 6 kg / cm. sq.
Hydrostatic pressure test: 10 kg / cm. sq for seat and ball sealing
20 kg / cm. sq for body sealing
Air leak test: 2 kg / cm. sq.
Spark test: 10 KV |